EN
105
ASC5100G
Troubleshooting
The display shows
“Max. filling time
exceeded!
Carry on?”
Message that appears during
the filling process if the set
amount of refrigerant cannot
be filled.
Check that
AirConServiceCenter con-
nections are not blocked.
The display shows
“External tank empty or
closed valve.
Check!”
Message that appears at the
start or during the filling of
the internal refrigerant con-
tainer if the set refrigerant
quantity cannot be attained.
Check if the external refriger-
ant container still contains
enough refrigerant or if the
valves of the external refrig-
erant container are open.
The display shows
“Change the equipment
drier filter!
Go on?”
This message appears when
you switch on the
AirConServiceCenter.
Change the internal filter as
soon as possible (see chap-
ter “Changing the dryer filter”
on page 91).
To skip this, press
ENTER
for
3 seconds.
The display shows
“Change the vacuum pump
oil!
Go on?”
This message appears when
you switch on the
AirConServiceCenter.
Change the vacuum pump oil
as soon as possible (see
chapter “Changing the vac-
uum pump oil” on page 96).
To skip this, press
ENTER
for
3 seconds.
The display shows
“Error 01”
Refrigerant was added
before draining was com-
pleted.
Repeat the draining proce-
dure; do not interrupt it this
time.
The display shows
“Error 02”
The air conditioning system
is leaking. There is still refrig-
erant in the air conditioning
system.
Fix the leak.
The display shows
“Error 52”
No USB stick was found/rec-
ognised
Insert the USB stick.
Make sure that USB stick has
been formatted with the
FAT32 file system.
Problem
Cause
Remedy
Summary of Contents for AirConServiceCenter ASC5100G
Page 2: ......
Page 220: ...RU ASC5100G 220 1 2 A I ENTER 1 2 3 1 2 3 1 229 230 2 A E...
Page 224: ...RU ASC5100G 224 2 3 405 C A AirConServiceCenters I R 1234yf...
Page 225: ...RU 225 ASC5100G 2 4 TRG 402 AirConServiceCenter...
Page 226: ...RU ASC5100G 226 2 5 AirConServiceCenter 230 50 2 6...
Page 230: ...RU AirConServiceCenter ASC5100G 230 6 2 10 11 12 13 11 10 13 12...
Page 236: ...RU ASC5100G 236 7 7 I 1 10 11 R 1234yf 11 10...
Page 243: ...RU 243 ASC5100G I 8 2 2 1 STOP ENTER USER CODE WRONG CODE John Citizen...
Page 257: ...RU 257 ASC5100G 10 D 11 E 12 15 13 14 D E...
Page 261: ...RU 261 ASC5100G 9 5 1 10 2 D E AirConServiceCenter D E D E...
Page 267: ...RU 267 ASC5100G 10 1 2 7 8 AirConServiceCenter 3 AirConServiceCenter AirConServiceCenter...
Page 268: ...RU ASC5100G 268 11 11 1 I 11 2 11 3 AirConServiceCenter M...