EN
59
ASC5100G
Safety
2.2
Operating the device safely
!
WARNING!
Do not operate the AirConServiceCenter in areas where there is a
risk of explosion (for example, battery charging rooms or spraying
booths), see operating safety directive BGR 157/TRG 250, 280, 316.
Do not pump compressed air into the refrigerant lines of the
AirConServiceCenter or the vehicle air conditioning system. A mix-
ture of compressed air and refrigerant can be flammable or explosive.
Maintenance and repairs to the unit may only be performed by quali-
fied and approved personnel from suitable and certified specialist
companies.
Risk of injury due to unplanned or unintended switching on of
the air conditioning service unit
Switch off the AirConServiceCenter prior to all maintenance work and
disconnect the mains cable from the mains supply. Pull the plug from
the socket or from the AirConServiceCenter.
Risk of burns from cold or hot components
Wear protective gloves.
!
CAUTION!
Do not start up the AirConServiceCenter if it is damaged.
Each time you start up the unit or top up the AirConServiceCenter,
first check whether the unit and all the service hoses are undamaged
and that all valves are closed.
Lay the service hoses in such a way that they pose no tripping hazard
for other persons.
Serious injuries due to overturning or falling load
The handle is not used to lift the unit. Only push the
AirConServiceCenter on rollers to transport it.
Always position the unit on level ground and secure the front wheels.
Only use approved refrigerant vessels with safety valves to refill the
AirConServiceCenter.
Always use the main switch of the AirConServiceCenter to switch it
on and off. Do not leave the device unattended when it is switched on.
Risk of injury from leaking fluids
Leaking fluids on the floor can cause persons to slip and injure them-
selves.
Wipe up leaked or dripped fluids immediately or absorb them with a
suitable binding agent.
Dispose of them in an environmentally sound manner.
Summary of Contents for AirConServiceCenter ASC5100G
Page 2: ......
Page 220: ...RU ASC5100G 220 1 2 A I ENTER 1 2 3 1 2 3 1 229 230 2 A E...
Page 224: ...RU ASC5100G 224 2 3 405 C A AirConServiceCenters I R 1234yf...
Page 225: ...RU 225 ASC5100G 2 4 TRG 402 AirConServiceCenter...
Page 226: ...RU ASC5100G 226 2 5 AirConServiceCenter 230 50 2 6...
Page 230: ...RU AirConServiceCenter ASC5100G 230 6 2 10 11 12 13 11 10 13 12...
Page 236: ...RU ASC5100G 236 7 7 I 1 10 11 R 1234yf 11 10...
Page 243: ...RU 243 ASC5100G I 8 2 2 1 STOP ENTER USER CODE WRONG CODE John Citizen...
Page 257: ...RU 257 ASC5100G 10 D 11 E 12 15 13 14 D E...
Page 261: ...RU 261 ASC5100G 9 5 1 10 2 D E AirConServiceCenter D E D E...
Page 267: ...RU 267 ASC5100G 10 1 2 7 8 AirConServiceCenter 3 AirConServiceCenter AirConServiceCenter...
Page 268: ...RU ASC5100G 268 11 11 1 I 11 2 11 3 AirConServiceCenter M...