Operation
28
6.5
Using the cooler
a
Caution – Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the
heat that generated during operation can dissipate. Ensure that
the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the
air can circulate.
➤
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the
heated air can dissipate.
➤
Close the cooler, see “Connecting the cooler” on page 26.
a
Caution – Danger from excessively low temperature!
Ensure that the only those objects are placed in the cooler that are
intended to be cooled at the selected temperature.
Locking the cooler
➤
Close the lid.
➤
Press the lock (fig.
5
1, page 4) down, until it latches in
place audibly.
Switching on the cooler
➤
Slide the sliding switch “BATTERY MONITOR” to HIGH if you
wish to operate from a starter battery or to “LOW” if you want to
operate from a supply battery.
I
Note
If you wish to operate the cooler from the AC mains, set the battery
monitor to the “LOW” position.
✓
The “POWER” LED is lit green.
✓
The cooler starts cooling the interior.
➤
Set the cooling temperature with the temperature controller
“TEMPERATURE”.
✓
CDF-18 only
: When the cooling temperature has been reached,
the “POWER” LED is lit yellow.