Operation
29
Switching off the cooler
➤
Empty the cooler.
➤
To Switch the cooler off: Slide the sliding switch “BATTERY
MONITOR” to “0”:
➤
Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
➤
Leave the cover slightly open. This prevents odour build-up.
6.6
Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the
vaporiser. This reduces the cooling capacity. Defrost the device in
good time to avoid this.
a
Caution – Danger of damaging the device!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤
Take out the contents of the cooling device.
➤
If necessary, place them in another cooling device to keep them
cool.
➤
Switch off the device.
➤
Leave the cover open.
➤
Wipe off the defrosted water.
6.7
Replacing the plug fuse (12/24 V)
➤
Pull the adapter sleeve (fig.
6
4, page 4) off of the plug.
➤
Unscrew the screw (fig.
6
5, page 4) out of the upper half of
the housing (fig.
6
1, page 4).
➤
Carefully raise the upper half of the housing from the lower
(fig.
6
6, page 4) half.
➤
Take out the contact pin (fig.
6
3, page 4).
➤
Replace the defective fuse (fig.
6
2, page 4) with a new one
that has the same rating (8A 32V).
➤
Re-assemble the plug in the reverse order.
_CDF.book Seite 29 Mittwoch, 15. September 2010 4:21 16