EN
CFX35 – CFX65DZ
Operation
41
6.11
Replacing the device fuse
D
➤
Pull off the connection cable.
➤
Pry out the fuse insert (fig.
4
2, page 4) with a screwdriver.
➤
Replace the defective fuse with a new one that has the same
rating (T4AL 250V).
➤
Press the fuse insert back into the housing.
6.12
Replacing the plug fuse (12/24 V)
➤
Pull the adapter sleeve (fig.
9
4, page 5) off of the plug.
➤
Unscrew the screw (fig.
9
5, page 5) out of the upper half of
the housing (fig.
9
6, page 5).
➤
Carefully lift the upper half of the housing off from the lower
(fig.
9
1, page 5) half.
➤
Take out the contact pin (fig.
9
3, page 5).
➤
Replace the defective fuse (fig.
9
2, page 5) with a new fuse
that has the same rating (10 A).
➤
Re-assemble the plug in the reverse order.
6.13
Replacing the light PCB
➤
Pry out the transparent cover with a screwdriver (fig.
0
1,
page 5).
➤
Unscrew the PCB mounting screws (fig.
0
2, page 5).
➤
Pull out the plug from the PCB (fig.
0
3, page 5).
➤
Replace the defective light PCB with a new one.
➤
Fit new PCB using reverse of removal instructions.
➤
Press the transparent cover back into the housing.
DANGER! Danger of electrocution!
Disconnect the connection cable before you replace the device
fuse.