13
GB
Specifications
CF-18
CF-25
CF-35
CF-40
CF-50
CF-80
CF-110
Art.-No.:
CF-018
CF-025
CF-035
CF-040
CF-050
CF-080
CF-110
Contents:
18 L
23 L
31 L
37 L
49 L
80 L
106 L
System:
direct evaporator
Temperature section
:
+10° C to -18° C
Weight:
11 kg
14 kg
15 kg
16 kg
18 kg
23 kg
25 kg
Power consump./h
power input x running time per hour
Running time per h
Ti = 5° C, Ta = 20° C
10 %
15 %
15 %
18 %
10 %
12 %
14 %
Ti = 5° C, Ta = 32° C
18 %
19 %
19 %
22 %
15 %
22 %
25 %
Nominal
DC 12 V 3,1 A
6,8 A
6,0 A
6,0 A
7,0 A
7,5 A
7,5 A
Current
DC 24 V 1,9 A
3,0 A
3,0 A
3,0 A
3,0 A
3,5 A
3,5 A
Nenns
AC 100-240 V
1,3~0,7 A
1,3~0,7 A
1,3~0,7 A
1,3~0,7 A
1,3~0,7 A
Manufactured
Injection moulded housing with integrated Rollbond evaporator; blow moulded lid; PU foam
materials:
insulation
Compressor
Fully hermetical Danfoss BD35F* compressor with control electronics and integrated low voltage
specification:
protection for 12 V and 24 V DC. Dynamic ventilated condenser, Aluminium Rollbond evaporator,
electronic reverse polarity protection, adjustable electronic thermostat
* CF-080, CF-110 = BD50F
Scope of delivery:
Operation manual Operation manual Operation manual, DC/AC-connection cable,
DC-connection
DC/AC-
wire basket, detachable handles
cable
connection cable
Drawings with dim.:
page 62
page 62
page 62
page 62
page 63
page 63
page 63
Battery controller:
The cool box is equipped with a battery controller cutting the compressor in or out in order to protect
battery and compressor.
Cut-out voltage:
low high
low med high
12 V
10,4 11,5
10,4 11,0 12,0
24 V
22,1 24,0
21,6 23,3 25,0
Cut-in voltage:
low high
low med high
12 V
11,5 12,5
11,2 12,0 12,9
24 V
23,6 25,4
23,0 24,5 26,3
manual 4445100020 03.11.2003 16:02 Uhr Seite 15