CoolMatic CRF-50
Setting up and connecting the freezer
27
➤
Connect the freezer
– as directly as possible to the poles of the battery or
– to a plug socket which is fuse protected with at least 15 A (at 12 V) or
7.5 A (at 24 V).
Caution!
Disconnect the device and other consumers from the battery
before charging the battery with a quick charging device.
Over voltages can damage the electronics of the device.
For safety reasons the freezer is equipped with an electronic system to pre-
vent the polarity being reversed. This protects the freezer against reversed
polarity when connecting to a battery and against short circuiting. To protect
the battery, the freezer switches off automatically if the voltage is insufficient
(see table below).
6.5
Connecting to a 230 V mains supply
Danger of fatal injuries!
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
If you are operating your cooling device on board a boat with a
mains connection of 230 V from the land, you must install a resid-
ual current circuit breaker between the 230 V mains supply and
the cooling device.
Get advice from a qualified specialist.
➤
To operate the freezer on the 230 V mains, use the WAECO MPS-35
rectifier.
12 V
24 V
Cut-off voltage
10.4 V
22.8 V
Cut-in voltage
11.7 V
24.2 V
CRF-50.book Seite 27 Montag, 27. September 2010 4:18 16