MBC-8IU, MBC-16IU
Cleaning and maintenance
41
8
Cleaning and maintenance
Caution – Danger of electrocution!
Always disconnect the mains plug before you clean and service the
device.
Caution – Danger of damaging the device!
Never clean the device under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the device.
➤
Occasionally clean the device with a damp cloth.
"F03" charging error
Current limitation
Electric consumers are
connected.
Disconnect all electric
consumers which are
connected to the battery.
"F04" charging error
Overheating
The compact charger has
become overheated.
Clean dirty ventilation
openings or remove objects
which are covering the device.
Place the compact charger in
a cooler location.
The compact charger restarts
automatically when it has
cooled down.
"F05" charging error
Charging time elapsed
The the battery charging time
is 24 hours.
Check the charging condition
of the battery.
The charging current selected
for the battery is too low.
Select a higher charging
current.
A battery cell is damaged.
Replace the battery. Dispose
of the defective battery in a
suitable manner.
Problem Cause
Remedy
MBC-8IU_16IU.book Seite 41 Dienstag, 6. September 2005 3:38 15