IU6, IU8, IU12
Hints on handling batteries
45
I
Note
The required charger strength depends on the battery capacity.
The rule of thumb is: 10% of the battery capacity in Ah/h is the min-
imum charging power of the charger.
For example, a 15 A device is suitable for battery capacities
between 40 and 150 Ah.
12.4
Avoiding battery
failure
Batteries can fail because they are not charged properly (negative
charging balance) or deep-discharged.
Failure due to negative charging balance
A negative charging balance can be caused by the following:
z
Insufficient charging by the lighting system due to undervoltage
(loss of voltage in the on-board electrics or defective and/or
incorrectly set voltage regulator)
z
Negative energy balance because too many electrical consum-
ers are used (the journey is too short for the alternator to
recharge the battery completely)
Failure due to deep discharge
Deep discharge can be caused by the following:
z
Consumer are not switched off
z
Self-discharge if the vehicle is not used for a long time (inde-
pendent of constant electric consumers)
Loss of power due to self-discharge depends on the battery.
However, self-discharging increases noticeably (by up to seven
times) as the temperature increases.
In the summer, this increased self-discharging due to increased
temperature, combined with constant consumers, can quickly
cause a deep discharge if the battery is not recharged using
the on-board device.
_IU6_IU8_IU12_BA_10s.book Seite 45 Mittwoch, 16. Januar 2008 2:06 14
Summary of Contents for PerfectCharge IU6
Page 3: ...IU6 IU8 IU12 3 1 2 5 3 4 _IU6_IU8_IU12_BA_10s book Seite 3 Mittwoch 16 Januar 2008 2 06 14...
Page 4: ...IU6 IU8 IU12 4 A B 6 _IU6_IU8_IU12_BA_10s book Seite 4 Mittwoch 16 Januar 2008 2 06 14...
Page 5: ...IU6 IU8 IU12 5 1 2 3 7 1 2 8 _IU6_IU8_IU12_BA_10s book Seite 5 Mittwoch 16 Januar 2008 2 06 14...