EN
113
VAS 6380B / VAS 6381B
Service tasks
9.3
Changing the dryer filter
1. In the basic menu, use the cursor keys
or
to select
“Free selection”
:
2. Press
ENTER
to confirm.
3. Skip the query requesting
“CAR DATA”
.
4. Select
“Rec/Recycling phase ?”
.
5. Set the
“Pressure increase test time”
to
“1”
.
Press
ENTER
to confirm.
6. Deselect
“Vacuum phase ?”
using
“No”
.
Press
ENTER
to confirm.
7. Deselect
“Filling phase?”
using
“No”
.
Press
ENTER
to confirm.
8. Select
“Process start ?”
.
Press
ENTER
to confirm.
The service hoses will now be drained and the AirConServiceCenter
basic menu will be activated. The compressor has produced a slight
internal vacuum so that the filter can be replaced with minimal refrig-
erant loss.
9. Pull out the mains plug.
10. Unscrew the screw (
D
) from the holder, and pull the dryer filter
straight out.
S h o rt s e l e c t i o n
□
F r e e s e l e c t i o n
■
O t h er s e l e c t i o n s
□
E N T ER - O K
⬍
D
WaecoVAS6380B-6381B_OPM_4445101232_EMEA(de-en-es-fr-ru)_202x-xx-xx.book Seite 113 Montag, 2. November 2020 1:46 13