User’s Manual—Read before using this equipment

hours example as above, then 50 amps is needed for 10 hours. This provides 
us with the basic amp-hours (AH) of battery that is required. Ten hours at 50 
amps equals 500 amp-hours (AH). There are additional factors that determine 
actual run time. These include: 

•  AC appliance load and time in use (basic AH). 
•  Cable gauge and length (cable losses). 
•  Charge level of the batteries (between use, chargers have to be able to 

fully charge the batteries). 

•  Temperature of the batteries (colder batteries provide fewer amps). 
•  Age and condition of the batteries (older batteries lose AH capacity). 
•  Compliance with turning off unnecessary AC loads. 
•  Use of DC appliances and compliance with turning off unnecessary DC 

loads. 

Derating the Battery Bank 

Most lead-acid batteries have a rating expressed in amp-hours (AH). The most 
common rating of AH is “at the 20 hour rate”. 

NOTE: Despite several internet explanations, there is no relationship between 
cold cranking amps (CCA) and ampere-hours (AH). 

For example, if a 20 AH battery is discharged at a 1 amp rate, is will take 20 
hours to discharge that battery. The terms “charged” and “discharged” relate 
to actual battery voltage. This means that the output voltage of a nominal 
12 volt battery starts at 13.4 volts (fully charged) then drops to 10.5 volts 
(discharged). If the load on the battery causes the battery to discharge faster 
than the 20 hour rate, the capacity (AH) of the battery is measurably reduced 
(derated). In heavy battery discharge applications, double the estimated Amp 
Hour rating and configure batteries to support this capacity. If the batteries 
are frequently charged by an alternator, the Amp Hour rating of the batteries 
required may be reduced. 

Configuring the battery bank 

Batteries that are used indoors or inside a vehicle or vessel, should be deep-
cycle, sealed lead acid batteries. 

NOTE: It is important that for any inverter installation to battery protection 
fuses. Battery fuses are added to the positive (+) battery cable as close as 
possible to the battery bank’s positive terminal. The fuse amperage rating 
must be sized to allow simultaneous operation of all the AC appliances 
to be powered, plus 20 percent safety factor. Fuses are very important to 
protect equipment, batteries and personnel. The fuses protect against battery 
explosion if the cables that connect to the inverter accidentally short. 

Battery Bank Diagram 

This Battery Bank diagram shows the use of 6 Volt Golf Cart batteries wired to 
deliver 12 Volts to the inverter. These batteries are flooded (venting) and vent 
to outside air. 

WARNING—Exploding Batteries!!

e

xploding

 

baTTeries

 

can

 

spray

 

molTen

 

lead

hoT

 

sulfuric

 

acid

and

 

oTher

 

meTal

 

and

 

plasTic

 

fragmenTs

baTTeries

 

ThaT

 

are

 

charging

 

or

 

under

 

high

 

discharge

 

raTes

 

produce

 

explosive

 

hydrogen

 

gas

 

inTo

 

The

 

surrounding

 

area

be

 

safe

fuse

 

The

 

baTTery

 

bank

 

and

 

make

 

sure

 

The

 

baTTeries

 

are

 

properly

 

venTilaTed

Summary of Contents for Elite 3000W

Page 1: ...Item 2206 User s Manual SHEMO080100244TXC ...

Page 2: ...h this level of power output This inverter has the highest surge capability in its class Superior surge capability of 6 000 watts allows the inverter to start most difficult motorized appliances Advanced microprocessor controlled circuits run cooler and are more reliable than competing units General Instructions Keep the inverter away from any direct heat source or combustible materials Keep well ...

Page 3: ...with multiple branches and AC outlets Any AC output wiring that is directly connected must comply with US National Electric Code NEC wiring gauge recommendations Facing the Front Panel the terminals are Neutral and Ground are bonded connected inside the inverter to comply with the NEC requirement that any AC source must have a Neutral to Ground connection Ground Terminal The Ground Terminal is loc...

Page 4: ... feature To enable the Remote Switch the front panel On Off Switch must be in the On position To turn On the inverter momentarily press ON To turn the inverter Off momentarily press Lock If the wireless remote fails to control operation of the inverter you may be out of range for the radio signal move closer to the inverter If the Remote Switch has a depleted battery open the unit by unscrewing th...

Page 5: ...ween battery bank and inverter Determining Maximum Appliance Wattage Microwave oven specifications list cooking power watts and appliance power Appliance power is the AC load the inverter has to supply Do not exceed the 3 000 watt maximum AC load or the inverter will shut down Most other electrical tools appliances and audio video equipment have labels that list the unit s power requirements in wa...

Page 6: ...nal 12 volt battery starts at 13 4 volts fully charged then drops to 10 5 volts discharged If the load on the battery causes the battery to discharge faster than the 20 hour rate the capacity AH of the battery is measurably reduced derated In heavy battery discharge applications double the estimated Amp Hour rating and configure batteries to support this capacity If the batteries are frequently ch...

Page 7: ...ch located on the front panel of the inverter is in the OFF 0 position 5 Locate the ground lug terminal on the inverter Connect an insulated 10 gauge copper wire to the terminal The other end of the ground wire is connected to a proper grounding point Use the shortest practical length of wire Connect this wire to the chassis of your vehicle or to the grounding system in your boat In a city the gro...

Page 8: ...may be necessary to charge a battery bank Regular Loss of Commercial Power If the inverter system is used during commercial power outages that occur daily configure the charger system to replace energy during the time that commercial power is available Replacement of battery energy always requires more than was taken from the battery typically 30 percent more Follow battery manufacturer s recommen...

Page 9: ...uous power output Unit may be defective See warranty and call customer service PROBLEM Inverter Shut Down Fault LED Lit OVL Display Reason Solution Equipment being operated draws too much power Use a higher capacity inverter or do not use this equipment PROBLEM Continuous Buzzing Sound Display Shows Low Voltage Reason Solution Input voltage below 10 5 Volts Keep input voltage above 10 5 Volts Poor...

Page 10: ... original store receipt The replacement product will be in warranty for the balance of the original two 2 Year warranty period To return a defective item please contact WAGAN Corporation at 800 231 5806 to obtain a Returned Merchandise Authorization number RMA and return instructions Each item returned will require a separate RMA After you have received the RMA and the return instructions from WAG...

Page 11: ...rd CA 94544 U S A U S Canada Toll Free 1 800 231 5806 Tel 1 510 471 9221 customerservice wagan com www wagan com 2012 Wagan Corporation All Rights Reserved Wagan Tech and wagan com are trademarks used by Wagan Corporation REV20120613 ...

Reviews: