background image

Power Dome 400W

10

USER’S MANUAL - Please read before using this equipment.

11

SPECIFICATIONS

  Sealed Lead Acid Battery  - Rechargeable 

12-Volt, 18 Amp Hour

  Work Light with On/Off Switch 

5x LED’s

  Compressor 

   

260 PSI Analog Gauge

  Inverter Output – Modified Sine Wave - Two AC outlets 

115 Volts AC  60Hz

  Maximum Inverter Output Power 

Peak Power

  400 Watts – 1000 Watts peak   

For a max of 0.3 sec

  12V Accessory Outlet 

   

12-volt 11 Amps max

  Max AC Charging Time from discharge 

34 hours

  Max DC Charging Time (engine operating) 

14 hours

  JumpStart Cables and Clamps  

6 Gauge, heavy duty clamps.

   

   

42 in length.

  Dimensions (LxWxH) 

   

10-3/4 x 8.5 x 12-5/8 in.)

   

   

(27.3 x 21.6 x 32.1 cm)

  Weight 

   

17 lbs 13.5 oz  (8.1 kg)

TROUBLESHOOTING GUIDE - INVERTER

  Trouble 

Cause 

Remedy

  Lack of power output 

Power Dome battery voltage below 

Recharge the Power Dome immediately.

   

10 volts.

 
   

Excessive current drawn by 

Reduce load to maximum of 400 watts.

   

appliance being operated.

   

   

1.  Turn OFF the device and inverter. 

   

   

2.  Disconnect device. 

   

   

3.  Turn the inverter ON and leave  

   

   

  running for a minimum of 2 minutes. 

   

   

4.  Turn OFF inverter, quickly plug in  

   

   

  device to inverter making sure device  

   

   

  is OFF prior to connection. 

   

   

5.  Turn ON the inverter and the device.

   

Inverter fuse blown. 

Check and replace if necessary. Be sure  

   

   

any replacement fuse is the same type 

   

   

and rating.

  Inverter Power Indicator 

Excessive voltage drop. 

Check Power Dome and recharge

  is not lit. 

   

if voltage drops below 10 volts.

   

Inverter is overloaded. 

Reduce load to maximum of 400 watts.

  Television/Power Tool 

High surge wattage requirement 

Toggle the On/Off switch in quick

  will not start 

to start-up. 

succession a total of five times. If the  

   

   

device does not start the device is not  

   

   

going to work with this type of inverter.

  Television Interference 

Picture breaking up (snow). 

Place the Power Dome as far as possible  

   

   

from TV, the antenna and the coaxial  

   

   

cable.

   

   

   

   

   

TV station may be out or range.

  Static/Noise interference  Sound system has weak alternating 

Do not use inverter with low quality

  in audio system 

current shielding. 

audio AC filtering system.

   

   

Replace audio system with high quality  

   

   

noise filtering.

Summary of Contents for Power Dome

Page 1: ...USER S MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE 400 Watt Power DomeCompact Generator Portable Power Source ...

Page 2: ...Volt Accessory Outlets for powering DC appliance loads to 18 Amps 6 1 USB power port 7 Bright Area light LED type for long battery life 8 AC Recharging Adapter 9 DC Recharging Adapter fused 10 Easy Read analog voltmeter for checking Battery Status 11 Jumpstart cable polarity indicator for safety FRONT VIEW Figure 1 shows the locations of the Compressor DC Power Outlets Battery Status Charging and ...

Page 3: ...sing the DC method 7 After charging the battery disconnect the adapter from the accessory socket first then from the charging jack 8 Replace the dust cover on the charging jack DC POWER PORT DC POWER PORTS accessory sockets are located under the Pressure Gauge and the Battery Status Meter voltmeter The ports can power a DC load of up to 11 Amps Overloading the port will result in tripping a self r...

Page 4: ...d close the dust cover 9 Recharge Power Dome as soon as convenient NOTES If the Power indicator LED is not lit then reduce the AC load If the inverter is still not operating refer to the troubleshooting table at the end of this User s Manual CAUTION Some rechargeable devices are equipped with a separate AC charger These devices will likely operate properly with this inverter Rechargeable devices t...

Page 5: ... vehicle 7 Observe the color of the REVERSE POLARITYLED that is located between the Battery Status and Work Light Switches 8 If the LED is RED DO NOT TURN ON THE CABLE JUMPER SWITCH Cable Clamps need to be reversed Disconnect the Black Clamp first and then the RED Cable Clamp Reconnect and observe the LED If the LED is green turn ON the Jumper Safety Switch 9 Inside the vehicle turn on the ignitio...

Page 6: ...nd inverter 2 Disconnect device 3 Turn the inverter ON and leave running for a minimum of 2 minutes 4 Turn OFF inverter quickly plug in device to inverter making sure device is OFF prior to connection 5 Turn ON the inverter and the device Inverter fuse blown Check and replace if necessary Be sure any replacement fuse is the same type and rating Inverter Power Indicator Excessive voltage drop Check...

Page 7: ...poration will at its option replaces or repair the defective part This warranty is void if the product has been damaged by accident in shipment unreasonable use misuse neglect improper service commercial use repairs by unauthorized personnel or other causes not arising out of defects in materials or workmanship This warranty is effective only if the product is purchased and operated in the USA and...