TROUBLESHOOTING
Reason
Solution
Poor contact with battery or inverter
terminals.
Clean terminals thoroughly. Reinstall and
tighten.
PROBLEM: Inverter Automatically Shut Down – Fault LED Lit
Reason
Solution
Battery voltage below 10V
Charge or replace battery.
Inverter is too hot.
(Thermal protection mode.)
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to rated
continuous power output.
Unit may be defective.
See warranty and call customer service.
Equipment being operated draws too much
power.
Use a higher capacity inverter or do not use
this equipment.
PROBLEM: Pulsing Alarm
Reason
Solution
Input voltage below 10.5V
Keep input voltage above 10.5V
Poor or weak battery condition.
Recharge or replace battery.
Poor or loose cable connection.
Inspect terminals and tighten all connections.
Inadequate power being delivered to the
inverter or excessive voltage drop.
Use heavier gauge DC cable.
Keep cable length as short as possible.