Page 1: ...S M O K E O P A C I T Y M E T E R 570 MONTROAL RD RURAL HALL NC 27045 336 969 6909 1 800 562 7024 US WWW WAGERUSA COM...

Page 2: ...TING SNAP ACCELERATION TEST PERFORMING A SNAP ACCELERATION TEST INTERFACE SOFTWARE APPENDIX A MAINTENANCE APPENDIX B VERIFICATION WITH NEUTRAL DENSITY FILTER APPENDIX C TROUBLE SHOOTING APPENDIX D SPE...

Page 3: ...ized repairs or alterations Equipment components and accessories made by other manufacturers are warranted only to the extent of the original manufacturer s warranties to Seller The foregoing warranty...

Page 4: ...l emission standards set by environmental air quality codes The program document for SAE J1667 is Surface Vehicle Recommended Practice It can be obtained from SAE International 400 Commonwealth Drive...

Page 5: ...ce of this unit as well as the SAE J1667 document To give you the opportunity to test the unit when it is received we have prepared the following Press SAVE Take the sensor head and the control unit o...

Page 6: ...nstruction Manual 194 0003 147 0166 147 0164 147 0165 194 0005 194 0016 F 194 0018 C 194 0018 S 194 0018 SC 194 0005 194 0004 192 0003A 191 0011 147 0150 2 147 C0092 147 0092 PF 544 0006 194 0029 2 19...

Page 7: ...ight situations the display can be backlit The display shows the prompts the operator follows throughout the test sequence s Up to 100 test can be stored in the system s memory The RS232 connection pe...

Page 8: ...the day s testing Extension Pole An extension pole is supplied with each system to allow the operator to attach the sensor head to the stack from the ground Carrying Case All the system s components...

Page 9: ...s infinite life expectancy Check filter provided for easy calibration All solid state electronics Manufactured by an ISO 9002 company Applications The Model 6500 Smoke Meter can be used on any diesel...

Page 10: ...the system curved straight and clamping styles The baynet straight nozzle hooks over the straight stack The curved nozzle has a stop that allows correct positioning The unit is held with strong magne...

Page 11: ...er is provided with the system Refer to appendix B for the description of this procedure Once the verification check has been complete return the filter to the protective sleeve The filter should be s...

Page 12: ...engine s specifications press SAVE If not press select until the correct rating appears Then press save 6 11 The display will give you the prompt START TEST and indicate T1 for the first test to be pe...

Page 13: ...rint the same test as often as you require Printing stored test at a later time is described in detail under Printing Saved Tests later in this section The printed test strip includes Record number Da...

Page 14: ...is not affected when the vehicle is in motion Follow Mode Test The Follow mode provides a means of providing a continuous real life opacity reading and performing tests under load either on the road o...

Page 15: ...one button on your printer On the control unit press and hold the PRINT button and then touch the ON OFF button The unit will display number of the last test performed Press SELECT to scroll to the re...

Page 16: ...er is not set to match the physical com port then the communication between the pc and the 6500 control unit will not function Once you have the configuration set to your desired setting click save an...

Page 17: ...download all the test records that are store in the control unit in one action It will not however give you the option to enter vehicle information and is therefore not recommend for snap test usage...

Page 18: ...s we have provided two snap closures The lenses can be wipes with a soft cloth We strongly recommend that a regular procedure of calibration and cleaning the lenses is established During light use a d...

Page 19: ...filter is an aluminum bar with holes at either end One of the holes contains the filter To measure the partial flow filter fully insert the bar glass end first into the small slot that is perpendicula...

Page 20: ...re If the control unit will not power on check to see if the battery is fully charged If yes check the fuse Error Messages CABLE FAILURE DISCONNECTED The light source is fully powered but no light is...

Page 21: ...E SOON The battery is getting low and needs recharging Action Recharge the battery or run the unit using the AC power adapter The unit will continue to function normally after displaying this message...

Page 22: ...W x 10 D x 4 H 5 Through the Stack Weight 5 0 lb 3 lb w o cables Control Unit Sensor Head Stack Clamp Assembly Range Warm up Time Response Time Display Response Time Chart Recorder Output Linearity Z...

Page 23: ...leration Test The engine is allowed to run at maximum RPM s for 4 to 5 seconds and brought back to idle Three snaps are taken for this test Each individual test is stored and a mathematical formula ap...

Page 24: ...imum on load terminal voltage supplied to the printer must be limited to 12V A full battery charge will take approximately 14 hours The printer incorporates a power saving feature which turn the print...

Page 25: ...lot and close the lid Ribbon Change The ribbon cassette will clip off on one side and can be easily removed After checking that the ribbon is taut clip it into position making sure that the paper stil...

Page 26: ...d and used in accordance with the instruction manual this equipment may cause interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer...

Page 27: ...following ZERO set time XXXXX your current time setting Press the ZERO for setting mode Press ZERO to change time format toggles between 12 and 24 hour clock Press the SELECT for hour mode Press ZERO...

Page 28: ...o scroll to your correct day 1 s digit Press SELECT to set year 10 s digit 06 12 98 Press ZERO to scroll to your correct year 10 s digit Press SELECT to set year 1 s digit 06 12 98 Press ZERO to scrol...

Page 29: ...Print Configuration mode Press PRINT for configuration print out Exit Configuration Mode Press START TEST to exit the configuration mode at any time Any changes you have made up to that point will be...