28
EN-USA_SECUSOL_TI-MA-111013-1121R800
X
X
For the C20 AR-M use the lowest rivet nut
and for L42 the one above the lowest.
Figure 25 Connecting collector and racking triangle
Installation of the Collectors on the Racking Triangles
Risk of injury from collapsing collector racks!
Make sure that the collector racks are properly
set up and all screws are fastened before pla-
cing the collectors. Improperly set up racking
triangles could collapse and lead to injuries of
limbs. Wear appropriate protective workwear!
Use appropriate wrench, e.g. combined
wrench 17 mm / 11/16 inch, such as Met-
rinch MET-1117. or adjustable spanner.
RISK of falling objects and structural damage
Improperly positioned collectors can lead to in-
sufficient fixation! Loosen collector clamp slight-
ly, then push tightly against collector and tighten
screw (12.5 lb-ft / 17 Nm). After installation check
for proper position.