Finishing, Proportioning and Pumping Solutions
colora
TRANSLATION OF THE ORIGINAL
OPERATING MANUAL
Automatic Air spray gun
Edition 03 / 2013
ASP 30
II 2G IIB T5
Table of different automatic guns
Nozzle size
ASP 30 MP
ASP 30 HVLP
0,8 mm
R955.08
R955.08H
1,0 mm
R955.10
R955.10H
1,2mm
R955.12
R955.12H
1,5 mm
R955.15
-
1,8 mm
R955.18
-
2,0 mm
R955.20
-
2,5 mm
R955.25
-
AIr SPrAy GuNS uSed for LIquId PAINTS IN Low/
MedIuM PreSSure APPLICATIoNS
This Operating Manual contains the instructions related to the
following models of automatic guns:
*
MP
= automatic Air spray gun - Medium Pressure version
*
HVLP
= automatic Air spray gun - HVLP version (High Volume
Low Pressure)
Use genuine parts and accessories only for best
function and safety.
Before starting,
read through all instructions carefully.
wArNING
Do not use halogenated hydrocarbons in coating application
equipment where aluminium or galvanized parts come in contact
with the solvent or coating material.
Halogenated hydrocarbons e.g. thrichloroethilene and
methylene chloride react violently with such parts, causing
corrosion and danger for explosion.
The high velocity flow of air and liquids through hoses and
nozzles may develop static electricity. Be sure that the equipment,
object being sprayed, spraybooth, paint and waste
container are properly grounded to prevent static discharge
or sparks.
As the equipment works under pressure all possible cares
must be observed during the work. Bearing this in mind, never
aim the spray gun at a person or towards any part of the body.
In case of personal injury caused by the pressure, immediate
medical attention is essential. Before carrying out any adjustment
or repair, the equipment must be switched off and the paint
pressure released.
NEVER exceed the maximum safe working pressure of the
equipment indicated in this Operating Manual.
The equipment must be used exclusively by skilled and
authorized staff.
CAuTIoN
Inhalation of paint, paint dust and solvent is not healthy.
Make sure an approved spraybooth is used. The staff must use
personal protection devices in accordance with the regulations in
force, both during work and during maintenance operations.
Read always carefully the classification slips and the
information related to safety and the use of the sprayed product
and follow all the recommendations. If you are not sure, call the
producer of the paint.
Wagner colora Srl would like to remind that a good knowledge of
the equipment will help you to operate it and that a correct use
of the appliance will avoid many problems, thus improving its
efficiency and prolonging its lifetime.
* T
he da
ta ma
y change without notic
e.
TeCHNICAL dATA
*
ASP 30 MP
ASP 30 HVLP
Max. fluid pressure
7 bar
7 bar
Min./Max. control air
pressure
4 / 7 bar
4 / 7 bar
Max. atomization air
pressure
7 bar
7 bar
Wetted parts
Stainless steel
Stainless steel
Min./Max. fluid
temperature
5 / 40°C
5 / 40°C
Weight
~ 520 g
~ 520 g