SPECIFICATIONS

Frequency

2.4 GHz

Protocol

BLE 5

Typical Read 

Range

up to 20 ft

or 6 meters

Dimensions

51 mm x 

95.45 mm x 

8.5 mm

Summary of Contents for Floor Sentry

Page 1: ...INSTRUCTION MANUAL BY WAGNER METERS FLOOR...

Page 2: ...TABLE OF CONTENTS 1 Introduction 5 Quick Start 8 Installation 13 Using the Wagner Sentry App 14 Summary of Floor Sentry Features 15 Specifications 20 Warranty 24 Glossary of Terms...

Page 3: ...H and serves as a data logging device that creates a historical record of temperature and RH If either the temperature or the RH falls outside the desired range for proper floor care and or avoiding p...

Page 4: ...oring may be at risk of damage or catastrophic failure if exposed to unfriendly ambient conditions This unwanted exposure can occur either from inside your home or building or from the underside of th...

Page 5: ...pically a crawl space or concrete slab foundation Keep in mind If ambient conditions primarily temperature and RH go beyond safe limits for extended periods of time significant damage to your wood flo...

Page 6: ...e temperature and RH of the wood flooring and the underlay ment subfloor Installing the Floor Sentry in your floor gives peace of mind that you will automatically receive alerts or notifications on yo...

Page 7: ...ith your new Wagner Floor Sentry is as easy as 1 2 3 Step 1 Install the Floor Sentry in your wood flooring using the included installation template Simply follow the instruction procedures and dimensi...

Page 8: ...6 Step 2 Download the Wagner Sentry app from either the Apple App Store or Google Play...

Page 9: ...Floor Sentry device its own unique name adjust the default settings as needed click the Device Installed button on the Device Settings screen and you are ready to begin monitoring temperature and RH a...

Page 10: ...er s router tool The Floor Sentry is installed in this cavity and then the plank is installed as normal Guidelines for determining the number of Floor Sentry devices to install Place one Floor Sentry...

Page 11: ...meter plunge router bit Ensure at least 0 125 1 8 of top flooring material is left above the cavity to help prevent undue stress if walked upon after installation Install the Floor Sentry in an area t...

Page 12: ...iture or other heavy objects The dimensions of the cavity to rout should be at least 2 1 5 3 cm wide 3 8 9 7 cm long and 0 38 9 7 mm deep With these allowances the minimum floor plank thickness would...

Page 13: ...sawdust or other debris first dry fit the Floor Sentry into the cavity to ensure proper clearance Then remove the release liner from the butyl seal and install into the cavity with the butyl seal sid...

Page 14: ...that no adhesives or other construction related materials interfere with the underside of the Floor Sentry Keep in mind that each side both top and bottom of the Floor Sentry contains a sensor Be sur...

Page 15: ...t conditions you will need to use the Floor Sentry device with the Wagner Sentry app The app can be downloaded for free from either the Apple App Store or Google Play For step by step instructions on...

Page 16: ...ry app for both iOS and Android devices Alerts or notifications when RH or temperature are outside the user defined alarm threshold Installation template with instructions and dimensions Capability to...

Page 17: ...15 SPECIFICATIONS Frequency 2 4 GHz Protocol BLE 5 Typical Read Range up to 20 ft or 6 meters Dimensions 51 mm x 95 45 mm x 8 5 mm...

Page 18: ...16 Weight 37 75 g 1 33 oz Lifetime of Battery Pack Up to 10 years depending on frequency of logging Storage Capacity 16 384 readings Measurement Interval 1 second to 136 years...

Page 19: ...17 SENSOR SPECIFICATIONS Humidity Accuracy Tolerance1 1 5 RH typ Resolution 0 1 RH...

Page 20: ...Accuracy Tolerance1 0 1 C typ 20 C to 60 C Resolution 0 1 C typ Repeatability2 0 04 C high typ From Sensirion datasheet 1 For definition of typical and maximum accuracy tolerance please refer to the S...

Page 21: ...epeatability is 3 times the standard deviation of multiple consecutive measurements at the stated repeatability and at constant ambient conditions It is a measure for the noise on the physical sensor...

Page 22: ...Sentry subject to the following terms and conditions Wagner Meters liability under this warranty shall be limited at Wagner Meters option to the repair or replacement of this product or any part there...

Page 23: ...or any defect in material or workmanship in this product shall be limited to the amount of purchase price of the product With proper care and maintenance the Floor Sentry s top and bottom sensors shou...

Page 24: ...IMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Under no circumstances shall Wagner Meters be liable for any incidental or consequential damages Agents and employees of...

Page 25: ...23 statements from an officer of Wagner Meters do not constitute warranties and should not be relied upon by the customer...

Page 26: ...The amount of water vapor in the air expressed as a percentage of the maximum amount that the air could hold at the given temperature Temperature The degree or intensity of heat present in a substance...

Page 27: ...25 NOTES...

Page 28: ...26 NOTES...

Page 29: ...27 NOTES...

Page 30: ...rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without...

Reviews: