© 1995 Wagner Spray Tech
6
All rights reserved.
Attaching the pump to the stand.
1.
Align the motor with the four holes on the back of
the stand assembly.
2.
Insert the four 5/16" x 1-3/4" screws through the
holes on the back of the stand legs. Install the
washer and nut over the end of each bolt and
tighten with an adjustable wrench. Install leg plugs.
1. Lock the gun by turning the gun safety switch so
that it is parallel to the gun body.
Locked position
Unlocked position
WARNING
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the gun
unless the tip is in either the spray or the unclog
position. Always engage the gun safety switch
before removing, replacing or cleaning tip.
2. Thread the spray tip onto the gun. Tighten the nut
first by hand, then tighten more firmly with an
adjustable wrench.
NOTE: When attaching the tip to the gun, align the
tip guard as shown in the figure below, then
tighten with an adjustable wrench.
1. Be sure that the motor switch is turned to OFF.
2. Screw the brass fitting of the return tube into the
upper port on the side of the pump. The brass fitting
is located in the literature set. Tighten firmly by
hand.
3. Press the return tube onto the brass fitting and
fasten the return tube with the clamp provided.
Screw
Washer
Nut
Leg Plug