119
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
13.5.2 SAFETY INSTRUCTION REMOTE CONTROL
The installation must be carried out in accordance with Chapter
. The following
safety instructions must be observed:
Safety instruction remote control
Do not open housing under voltage.
Open housing only in the absence of a potentially explosive atmospheres.
The gap distance from cover-housing bottom to fixed obstacles must be at least 3 cm;
1.2 inches.
The remote control must be securely assembled, the line must be laid firmly and
with protection from mechanical damage. (For example not laid in the area of aisles
or walkways, not on driveways from product handling vehicles, not through doors/
gates.)
The first attachment point of the cable should be no more than 30 cm; 12 inches
away from the housing.
Extension cable: lengthen to a maximum of 2 times 15 m; 49 ft. (Total 45 m; 147 ft.)
The plug connectors of remote control and extension cable must be located in non-
potentially explosive areas.
Grounding
: ground the housing via a separate line (cross-section 4 mm²; 0.0062 sq in),
connect on the local equipotential bonding (see grounding schemas in Chapter 6.5).
Warning
: Any repair by a repair shop according to EN 60079-19 is not possible due to
flame path gaps smaller than the maximum permitted by EN 60079-1.
Contact the WAGNER service center in Markdorf (Germany) if a repair is necessary.
NOTICE
Magnetic fields!
Danger of damage to electronic devices and magnetic data carriers.
Ensure that electronic devices and magnetic data carriers are removed from the danger
area of the magnetic pin.