7.13.2 PASSWORD LEVEL 3 SETTINGS
Menu
Level 3
There are 23 pages of settings. (Detailed descriptions of these pages can be found in the
2K COMFORT Software Documentation.)
1
2K
-
, 3K-
or
4K
system (with 2-circuit system maximally 3K)
Measuring units
for volume (liters / US gallons) and lengths (meter / inch)
Gun closed
Valves closed
"On": When the gun is closed, all product valves are
also closed automatically. Beneficial for low-pressure applications. Prerequisite: gun
monitoring (not flow monitor).
External release
"On" = External releasing (e.g. locking with spray booth's exhaust air)
Number of installed Universal CAN I/O modules
2
Number of guns
(1–4, with 2-circuit system 1–2)
Gun monitoring
for all available guns.
Splitter valve
(Prerequisite: minimum 2 guns)
Flush guns separately
"On" = splitter valve with flushing (separate gun flushing
valves). Prerequisite: maximum 2 guns, splitter valve = On.
Number of
gun flush boxes (GFB)
Automatic flushing at pot life alarm
(Prerequisite: GFB)
Flow monitoring
(On/Off). Prerequisite: gun monitoring or flow monitor. Sets off
Alarms A121 and A122. ("Alarm delay for flow monitoring" Chapter
, level 2,
page 2. Enter the limits in the paint recipe see Chapter
)
3
Dump valve
"On" = There is a dump valve installed for every gun.
Or a dump valve
flushable.
If a dump hose is present between gun and dump valve (not flushable), the
option
dump valve as return line
is activated.
Dump valve for waste separation
is possible with double valves (not flushable) (not for 2-circuit system).
Precision of
waste separation
: 0 = exact, each additional number = 25% of the dump hose safety
margin (default value 2).
Dump valve outputs can be inverted
"Off" = Compressed air opens dump valve
with non-flushable dump valves without waste separation.
"On" = Compressed air closes dump valve.
4 For component A:
Number of
valves
and
flushing valves.
Minimum and maximum
flow
. Sets off Alarms A106 to A113. (Delay time "Gun Delay"
see Chapter
, level 2, page 1)
Air bubbles monitoring
(On/Off)
Coriolis
flow meter
Flow measurement with
stroke sensors
(On/Off), from software version 4.0x / 4.0x K.
To configure stroke sensors: see 2K COMFORT software documentation.