82
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
Start other flushing recipes
For electrostatic spray guns: switch off electrostatics.
On the screen's home page.
Depending on the configuration, various selection possibilities appear:
−
Manual flushing:
select a recipe from the list of all recipes.
−
Start end flushing
: starts end flushing of the last paint recipe used.
−
Start flushing external mixer
: flushing from external mixer. The product hoses between
valves and mixer are not flushed.
−
Flushing spray guns
: flushing from splitter valve. The product hoses between valves
and splitter valve are not flushed.
Flushing with dump valve (option)
Flushing via a dump valve is quicker than via the gun. However, the gun has also to be
flushed briefly.
When the flushing process stops and the spray gun symbol on the screen flashes, the
corresponding guns have to be opened. Point opened gun(s) with or without nozzle
in a waste tank.
B_05236
As long as the gun symbol
flashes, open the corresponding
spray gun (here gun 2).
Step
1
2
As soon as the gun symbol stops flashing, close gun again.
Flushing with gun flush box
Same procedure as without gun flush box, but:
Before flushing, insert the spray gun into the gun flush box.
− Atomizing air flushing: the flushing pause indicates when the gun is to be inserted
into the gun flush box.
Remove the spray gun after flushing.