© 2001 Wagner Spray Tech. All rights reserved.
7
English
CLEANING THE SUCTION EXTENSION
1. Make sure the sprayer is unplugged.
2. Remove the suction set from the material container and
submerge into a container of the solvent appropriate to the
type of material you sprayed.
3. Plug in the sprayer, and squeeze the trigger and spray into
a second container until the solvent coming through the
sprayer is free of material.
4. Unplug the sprayer.
5. Remove the suction set from the cleaning solution.
6. Unlock the pump housing locking nut by turning it
counterclockwise.
7. Pull the dual hose fitting out of the pump housing.
CLEANING THE PUMP HOUSING
1. Make certain the sprayer is unplugged.
2. Turn the spray tip
counterclockwise
until it is removed.
Be careful not to lose the swirl valve.
3. Pull out the swirl valve.
4. Turn the locking nut
counterclockwise
until it is removed.
Locking nut
Pump
housing
opening
Swirl valve
Spray tip
Dual hose
fitting
Locking
collar
5. Slide the pump housing assembly off of the sprayer.
6. Pull the piston and spring off of the pump housing.
7. Pull the spring off of the piston.
8. Remove the fluid container and suction set.
9. Clean all parts thoroughly with the brush provided using a
solution appropriate to the type of material you sprayed.
Make sure to completely remove all material from the inside
of the piston chamber by scrubbing with the brush. Even a
small amount of material can dry like glue and keep the
piston from moving, causing damage to the sprayer.
Make sure to keep the vent hole on the pump housing clean
and unblocked or a vacuum can build up in the container
and cause damage to the sprayer. A toothpick or
straightened paper clip can be used to clean it.
Vent hole
Cleaning
brush
CAUTION
Piston
Spring
Pump housing
Locking nut
Swirl
valve
Spray tip