AG-08 TS
11
GB
conditions exist. Never repair a paint hose. Replace it with another grounded high-
pressure hose.
8. Pulling the trigger causes a recoil force to the hand that is holding the spray gun.
The recoil force of the spray gun is particularly powerful when the tip has been removed
and a high pressure has been set on the airless high-pressure pump. Therefore, when
cleaning without tip set the pressure control valve to the lowest pressure.
9. Use only manufacturer authorized parts. User assumes all risks and liabilities when using
parts that do not meet the minimum specifications and safety devices of the spray gun
manufacturer.
EXPLOSION PROTECTION IDENTIFICATION
X marking:
The spray gun corresponds with Ex II 2G X and is, in accordance with Directive 94/9/EEC
(Atex 100a), suitable for use in explosion-hazardous areas—as of type Zone 1. Under
certain circumstances, the unit itself may cause the Zone 1 condition to be in effect.
Any static-electricity discharge from the spray gun is to be diverted to the grounded high-
pressure pump via the conductive high-pressure hose as stipulated.
The maximum surface temperature corresponds to the permissible material temperature.
This and the permissible ambient temperature can be found in the Technical Data.
To avoid the generation of machine sparks, prevent impact stresses and any work on the unit
with tools in the explosion-hazardous area.
Residual risks
Residual risks are risks, which cannot be excluded, even when equipment is used for the
intended purpose.
In such cases the applicable areas of the actual residual risks will be pointed out using warning
and/or prohibition signs.
Risk
Source / Cause
Impact
Preventative measures
Can occur
during:
Injection
injury
Atomized, high
pressure stream of
fluid
Severe
injury or
amputation
NEVER aim the gun at
any part of the body
Setup,
Operation
Explosion or
fire
Static electricity or
sparks
Severe
injury
Use well ventilated area
Ground the spray gun
Operation
Hazardous
vapors
Hazardous vapors
from spray material
Severe
injury
Use well ventilated area
Use mask
Operation
Technical Data
Max. operating pressure
25 MPa (3600 PSI)
Material inlet thread size
M16 x 1.5 (NPSM 1/4”)
Diffuser thread size
7/8 - 14 UN-2A
11/16 - 16 UN-2A
Wetted parts material
High-grade steel, aluminum, PTFE, hard metal
Operating temperature range
5ºC to 40ºC (40ºF to 104ºF)
Maximum material temperature
43ºC (109ºF)
Maximum sound output
81 dB(A)*
Weight
450 g (1 lb.)
* Measurement location: 0.5 m away from the coating surface, 0.5 m behind the spray gun,
spray pressure 12 MPa, tip size 0.021
Summary of Contents for AG-08 TS