background image

12 

AG-08

GB

Introduction

This airless spray gun is to be used for the high pressure atomization of liquid coating materials.

The spray gun corresponds with Ex II 2G X and is, in accordance with Directive 94/9/EEC 

(Atex 100a), suitable for use in explosion-hazardous areas—as of type Zone 1.  Under certain 

circumstances, the unit itself may cause the Zone 1 condition to be in effect.

X marking:  Any static-electricity discharge from the spray gun is to be diverted to the grounded high-

pressure pump via the conductive high-pressure hose as stipulated.

To avoid the generation of machine sparks, prevent impact stresses and any work on the unit with 

tools in the explosion-hazardous area.

Using the Gun Trigger Lock

Always engage the gun’s trigger lock when the gun is not in use.

1.  To lock the trigger, rotate the trigger lock forward until it stops.  

2.  To unlock the trigger, rotate the trigger lock backward until it is vertical.

Trigger locked  

(gun will not spray)

Trigger unlocked 

(gun will spray)

Setup

Never attempt to assemble, change, or clean the gun, tip, or tip guard without first 

relieving pressure from the spray system.  Follow the “Pressure Relief Procedure” in 

the sprayer’s Owner’s Manual.

Always use a tip safety guard for added protection against injection.  Beware that the 

guard alone will not prevent injection.  Never cut off tip guard!  Always engage gun 

trigger lock when the gun is not in use.  Before servicing equipment, consult Owner’s 

Manuals and follow all warnings.

  1.  Set up the sprayer.  Refer to the instructions in the sprayer’s Owner’s Manual.

  2.  Attach a grounded, airless spray hose to the material inlet on the gun.  Using two wrenches 

(one on the gun and one on the hose), tighten securely.

Tip Seal

Seal

Tip

Tip 
Guard

3.  With the tip and tip guard off the gun, start the sprayer.  Flush 

and prepare the spray system according to the sprayer’s 

Owner’s Manual.  Inspect the spray system to make sure that 

all fittings are secure and that there are no leaks.

4.  Perform the “Pressure Relief Procedure” described in the 

sprayer’s Owner’s Manual.

5.  Using a pen or similar object, insert the tip seal and seal into 

the back of the tip guard.  Press in for final adjustment.

6.  Insert the tip into the slot on the tip guard.

7.  Thread the tip guard onto the gun.  Position the tip guard in 

the desired spraying position, then tighten securely.

i

The arrow on the tip handle should be pointing 

in the forward direction for spraying. 

Summary of Contents for AG-08

Page 1: ...usuario Gebruikshandleiding Ejermanual Anv ndarmanual Model Numbers G THD 1 4 0296362 G THD 1 4 no tip 0296386 G THD 1 4 no tip 2 Fgr 0296467 F THD 1 4 0296393 F THD 1 4 no tip 0296388 F THD 1 4 no ti...

Page 2: ...VER use a spray gun without a trigger lock and trigger guard in place and in good working order All accessories must be rated at or above the maximum operating pressure range of the airless sprayer Th...

Page 3: ...pump Therefore when cleaning without tip set the pressure control valve to the lowest pressure 9 Use only manufacturer authorized parts User assumes all risks and liabilities when using parts that do...

Page 4: ...spray system Follow the Pressure Relief Procedure in the sprayer s Owner s Manual Always use a tip safety guard for added protection against injection Beware that the guard alone will not prevent inje...

Page 5: ...ved and replaced easily without disassembling the gun Never attempt to change or clean the tip or tip guard without first performing the Pressure Relief Procedure 1 Perform the Pressure Relief Procedu...

Page 6: ...inst a metal container while flushing Maintenance Follow all safety precautions as described in the Safety Precautions section of this manual before proceeding i Refer to the Parts List section in thi...

Page 7: ...and the rear housing while pulling the trigger Replacing Removing the Filter 1 Pull the bottom of the trigger guard forward so that it comes loose from the handle assembly 2 Loosen and remove the han...

Page 8: ...ft operations in particular or in the event of rentals it amounts to 12 months Systems driven by petrol or air are also guaranteed for a 12 month period The guarantee period begins with the day of del...

Page 9: ...cations or additions have been carried out for products where the serial number has been removed or is illegible for products to which attempts at repairs have been carried out by unauthorised persons...

Page 10: ...8 Diffuser 7 8 Diffuseur 7 8 0296406 Diffuser 11 16 Diffuser 11 16 Diffuseur 11 16 7 0508423 Dichtung Seal Joint 8 0552419 D se komplett mit Teil 7 und 10 Tip assembly includes items 7 and 10 Buse com...

Page 11: ...embly 2 finger gun Col pistolet 2 doigts 22 0271xxx 2 Speed Tip 2 Speed Tip 2 Speed Tip 23 0271065 2 Speed Tip Halterung 2 Speed Tip holder 2 Speed Tip support Wird nicht mit allen Farbspritzpistolen...

Page 12: ...7269 Gr nstadt Tel 0 63 59 87 27 55 0 Telefax 0 63 59 80 74 80 Europa Servicenetz A B CH J Wagner GmbH Oberfl chentechnik Lohnergasse 1 1210 Wien Austria Tel 0043 1 2707781 0 Fax 0043 1 2788430 office...