74
OPERATING MANUAL
EDITION 02/2016
ORDER NUMBER DOC 2366600
1.
Switch off control unit.
2.
Relieve pressure Chapter 7.3.4.
3.
Secure the spray gun (1) using the trigger lock (14).
4.
Unscrew union nut (12) with air cap (10) and ACF5000 nozzle (11).
5.
Remove air cap (10).
6.
Push ACF 5000 nozzle (11) out of air cap (10) by hand, reverse it and put it into the
air cap (10) with the nozzle tip towards the rear. Pay attention to the position of the
guide surfaces (X).
7.
Insert air cap (10) with integrated ACF 5000 nozzle (11) into the union nut (9).
Make sure that the air cap horns (Y) lie in the recess of the nozzle guard.
8.
Screw preassembled union nut (12) to gun (1) and tighten by hand.
9.
Switch the product pressure back on.
10. Turn the trigger lock (14) to the spraying position and briefl y pull the trigger.
11. When the blockage has been fl ushed out, secure the gun with trigger lock (14).
12. Relieve pressure Chapter 7.3.4.
13. Unscrew union nut (12) completely.
14. Remove air cap (10) and push ACF 5000 nozzle (11) out of the air cap by hand.
Clean ACF5000 nozzle and insert it in spraying position into the valve housing.
15. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces (X).
16. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
17. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
18. Switch the product pressure and the air pressure back on.
19. Switch on the control unit.
7.3.10
ELIMINATE NOZZLE CLOGGING
Summary of Contents for AquaCoat 5010
Page 2: ......
Page 72: ...72 OPERATING MANUAL EDITION 02 2016 ORDER NUMBER DOC 2366600...
Page 159: ......