24
AquaCoat GM 5000EACW
AquaCoat
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R2
R1
Zerstäuberluft
Atomizing air
Mat. Druckregler
Mat. pressure reg.
Pumpe
Pump
POWER
0
1
B_03364
21
17
15
22
12
24
25
3
5
20
10
9
11
6
1
16
18
13
14
19
23
2
4
7
8
26
27
OPERATING MANUAL
EDITION 04/2012
PART NO. DOC2321362
4.4.1.1
CONTROL UNIT VM 5000W
The assembled spray system can be operated and regulated with the VM 5000W control
unit.
Operating elements on the front:
1
Selector (mains supply)
0 = control unit switched off
1 = control unit switched on.
2
Universal rotary controller
●
Dynamic digital rotary controller with 32 positions per revolution.
●
Adjustment speed is proportional to rotational speed.
●
Used to adjust high voltage and spray voltage.
●
For setting parameter values in confi guration mode.
3 Push
button
“Standby“
To switch to stand-by mode.
4 Illuminated
display
“Standby”
Lights up when the unit is in standby mode.
5
Push button “Spraying current”
To activate the function, the current limiting is set with the rotary controller (2) and is
indicated in the LED display (27).
●
Adjusting range: 10 - 100 µA
●
Resolution: 1 µA.
6
Illuminated display “Spraying current”
Summary of Contents for AquaCoat AirCoat GM 5000EACW