OPERATING MANUAL
EDITION 04/2012
PART NO. DOC2321362
5.3.2.2
SPRAYPACK EXAMPLES WITH DOUBLE DIAPHRAGM PUMP COBRA 40-10
Check the unit for leaks:
1. Place container (13) with suitable detergent into the AquaCoat cabinet.
2. Immerse in container the suction system (12).
3. Connect the earth.
4. Connect the AquaCoat system to the compressed air source (8).
5. Set a maximum pressure of 0.6 MPa; 6 bar; 87 psi on the control unit of the Cobra 40-10.
6. Maintain the pressure for 5 minutes and check all connecting parts for leaks.
7. When the tightness of the system has been ascertained, release the spray gun (4).
8. Flush system through well.
9. Relieve system pressure and secure the spray gun (4).
10. Remove the detergent.
Cobra 40-10 vertical mounted
with suction system