SETTING THE CURRENT LIMITING
Works procedure:
1. Press the „Current limiting“ button (5)
to adjust the limitation of the spray
current. The LED (6) indicates that
current limiting is selected.
2. The current limiting can now be
adjusted using the universal rotary
controller (2) between 10 - 100 µA with
a resolution of 1 µA. The value is shown
in the LED display (27).
Above the „current limiting“ button (5) is the „Current limiting“ bar graph display (22). When
the control unit is in the ready position, this display shows the set point as a dot.
The current limiting is an adjustable threshold. If this threshold is exceeded, for example by
approach of the spray gun to the spraying object, the high-voltage is adjusted downwards
until the threshold is no longer exceeded.
The values set in the examples for target high voltage at 40 kV and current limiter at 83 µA
are stored in R2 through prolonged pressing of the recipe pushbutton (> 2 sec.).
Summary of Contents for AquaCoat AirCoat GM 5000EACW
Page 2: ......
Page 38: ...38 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Page 92: ...92 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Page 101: ...101 AquaCoat GM 5000EACW OPERATING MANUAL EDITION 04 2012 PART NO DOC2321362 ...
Page 111: ......