Functional fault
Cause
Remedy
Poor wrap-around
• Poor earthing at object
• Check earthing of object or hanger with
ohmmeter
• Paint resistance too high / too
low
• Check resistance of paint
see chapter 4.1.1
• Spraying pressure too high
• Readjust spraying pressure
Back spraying
• Object not earthed
• Check earthing
• Distance between spray gun
and object too large
• Reduce distance between spray gun and
object
• High voltage set wrongly (too
high)
• Adapt high voltage to material
No wrap-around
• No high voltage
• Repair malfunction as laid down in the
control unit operating instructions
• Seal in end piece defective
• Repair by Wagner Service Center
• Air-passages damp
• Cleaning air-passages and drying
Ventilstange undicht
• Dichtungen der Ventilstange
beschädigt
• Replace the seals (see chapter 8)