Activities
Aid tools
7. Test door lock
●
Main switch off.
●
Air on.
●
Main switch on => door locked.
●
Main switch off => door unlocks.
8. Test
spraying
●
Fit door.
●
Main switch on.
●
Set high voltage to 5 kV.
●
Remove gun.
●
With the gun removed, gradually increase the high voltage up to
maximum voltage (70 kV).
No more than one LED must illuminate on the current indicator (10µA).
●
Main switch off.