GB
29
W 687 E
Malfunction
Cause
Remedy
Device does not
function
Device overheated
•
Unplug the power
➞
plug, let the device
cool down approx. 30
minutes, do not bend
the hose, check the air
filter, do not cover the
intake slots
Poor covering
capacity on the
wall
Spray material is too cold
•
Highly absorbent surface or paint
•
with poor covering capacity
Distance too large
•
Heat spray material
➞
(to
maximum 40°C
)
Cross spray (Fig. 11)
➞
Closer to the object
➞
Warning
If the supply cord of this appliance is damaged, it
must only be replaced by a repair shop appointed by
the manufacturer, because special purpose tools are
required.
Warning:
Do not connect the blue or brown wire to the
earth terminal of the plug! The wires in this mains lead
are coloured in accordance with the following code:
blue
= neutral
brown
= live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifiying the terminals in your plug,
proceed as follows:
Should the moulded plug have to be replaced, never
re-use the defective plug or attempt to plug it into a
different 13 A socket. This could result in an electric
shock.
Should it be necessary to exchange the fuse in the plug
only use fuses approved by ASTA in accordance with
BS 1362. 5 Amp fuses may be used.
To ensure that the fuse and fuse carrier are correctly
mounted please observe the provided markings or
colour coding in the plug.
After changing the fuse, always make sure that the
fuse carrier is correctly inserted. With out the fuse
carrier, it is not permissible to use the plug.
The correct fuses and fuse carriers are available from
your local electrical supplies stockist.