9. To exit the configuration mode, press the [Standby] button (15) twice. The control unit
is now in the operating mode with high powder feed switched on. This setting is global
and applies in all recipes.
7.5 CHANGING AND SAVING RECIPES
7.5.1 Recipe Nos. 1 - 4
2x
2x
P_01750
5
6
7
8
Recipes 1 – 4 can be selected and saved directly using recipe buttons 5 – 8. Once the recipe
required has been called up, the individual coating parameters can be called up and
changed using the corresponding selection buttons. Descriptions of the individual
parameters are provided in Chapter Setting the Total Air Volume [
39] and in the
following chapters. When a parameter is changed, the LED on the left of the recipe button
flashes to indicate to the user that a parameter value has been changed.
The process for saving parameters is described below.
– To reuse the originally set values, press the corresponding recipe button briefly. The
modified values are not applied.
– To save the modified values, press the appropriate recipe button and hold for approx. 2
seconds until the LED beside the button flashes quickly. The modified values are then
saved.
7.5.2 Recipe Nos. 5 - 50