Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
Order number 2354913 | Edition 10/2022
47
This function is set to the [OFF] parameter value in the factory. The values can be changed in
the parameter settings for parameters C22 and C23 (see Chapter Appendix Device
Configuration [
7.7.2 Cleaning Flush Function
This function is used at the end of a shift or during a paint change. All powder feed parts are
flushed. The flushing process is as described below:
First the atomizing air is activated. After around 0.5 seconds, the feed and dosing air are
added, increasing all the time. After a total of 2.5 seconds, the feed and dosing air flush in
pulses while the atomizing air remains constant throughout.
The cleaning flush function is only available when the control unit is switched on and in the
operating mode. In standby mode or in configuration mode, this function is inactive.
7.7.3 Procedure for Cleaning Flushing with Manual Guns
P_01759
EPG
SPRINT X
0
%
10
20
30
40
50
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
80
100
%
Tri
90
60
70
35
34
18
15
17
1. End coating operation.
2. Remove powder suction unit (suction lance, powder injector) from powder tank.
3. Switch on flushing function by pressing [Flushing] button (17) on the control unit.
ð
LED display (18) lights up permanently.
4. Close function by again pressing [Flushing] button (17).
The activated function is also indicated by the [Total air] illuminated display (34) and