Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
17 Brief description
78
Order number 2354913 | Edition 10/2022
17.2 OPERATION OF THE CONTROL UNIT
1 Changing Parameters
1. Use selection button to select the parameters required.
ð
The yellow LED lights up.
2. Set parameter value with control dial.
ð
The value set is shown in the LED display.
2x
2x
2x
2x
2 Calling Up / Changing / Saving Recipes 1 – 4
1. Select required recipe by pressing the corresponding recipe button.
2. Set new parameters (electrostatic, air volume) (see 1).
3. Press the recipe button required for around 2 seconds until the LED display flashes
rapidly.
ð
The recipe is saved with new parameters and can be called up again at any time at
the touch of a button.
3 Calling Up / Changing / Saving Recipes 5 – 50
1. Press Additional Recipes button.
2. Set recipe number with control dial.
ð
The recipe number is displayed in the LED display.
3. Set new parameters (see 1).
4. Press Additional recipes button for around 2 seconds.
ð
The changed parameters are saved.
ð
The recipe number is shown flashing in the LED display.
5. Set desired recipe number with control dial.
(Only necessary if the parameters are to be saved under another recipe number.)
6. Press Additional recipes button for around 2 seconds.
ð
LED display flashes quickly.
ð