CORRECTION OF MALFUNCTIONS

MALFUNCTION

CAUSE

REMEDY

The unit will not start

• 

No mains voltage

• 

Device overheated

• 

Check

• 

Unplug the power plug, let the device cool 

down approx. 30 minutes, do not bend the 

hose, check the air filter, do not cover the intake 

slots

No coating material emerges 

from the nozzle

• 

Nozzle clogged

• 

Material volume setting too low

• 

Paint container seal damaged

• 

No pressure build-up in container

• 

Container empty

• 

Ventilation hose loose/damaged

• 

Feed tube loose

• 

Feed tube / feed tube filter clogged

• 

Air vent on feed tube blocked

• 

Diaphragm stuck

• 

Clean

• 

Increase volume

• 

Replace

• 

Tighten container

• 

Refill

• 

Insert or replace

• 

Insert

• 

Clean or use another filter

• 

Clean

• 

Remove and clean (see section 13.2)

Coating material drips from the 

nozzle

• 

Air cap, nozzle or needle soiled

• 

Spray attachment incorrectly 

assembled

• 

Nozzle loose

• 

Nozzle worn

• 

Needle worn or damaged

• 

Clean 

• 

Assemble correctly (see section 12.1) 

• 

Tighten Union nut

• 

Change

• 

Replace the needle (service set 2434517)

Atomisation too coarse

• 

Material volume too large

• 

Nozzle contaminated

• 

Viscosity of coating material too high

• 

Too little pressure build-up in 

container

• 

Air filter heavily soiled

• 

Amount of air too low

• 

Air hose damaged

• 

Air cap assembled incorrectly

• 

Reduce volume

• 

Clean

• 

Dilute further

• 

Tighten container 

• 

Change (see section 13.1)

• 

Increase volume

• 

Check and replace if necessary

• 

Snap air cap properly into place (fig. 17)

Spray jet pulsates

• 

Coating material in container running 

out

• 

Nozzle seal worn

• 

Air filter heavily soiled

• 

Feed tube loose

• 

Feed tube / feed tube filter clogged

• 

Refill 

• 

Replace

• 

Change (see section 13.1)

• 

Insert

• 

Clean or use another filter

Coating material causes “paint 

tears

• 

Too much coating material applied

• 

Distance too small

• 

Incorrect spray attachment

• 

Reduce volume

• 

Increase distance

• 

Use another spray attachment

Excessive paint mist (overspray)

• 

Distance to the object too large

• 

Too much coating material applied

• 

Amount of air too high

• 

Coating substance over-diluted

• 

Incorrect spray attachment

• 

Reduce distance

• 

Reduce volume

• 

Reduce volume

• 

Reduce degree of dilution

• 

Use another spray attachment

Paint in the ventilating hose

• 

Diaphragm soiled

• 

Diaphragm defective

• 

Clean the diaphragm (see section 13.2)

• 

Replace the diaphragm (see section 13.2)

CORRECTION OF MALFUNCTIONS

Summary of Contents for FinishControl 5500

Page 1: ...FINISH CONTROL 5500 OPERATING MANUAL wagner group com EN...

Page 2: ...FinishControl 5500 1 1 2 3 A A B 1 c 24 3 2 11 12 1 13 9 5 4 14 23 18 25 7 6 8 15 16 17 19 20 21 22 10...

Page 3: ...FinishControl 5500 A B 2 1 1 1 1 3 10 cm 1 2 1 2...

Page 4: ...FinishControl 5500 r 1 q 1 s 1 3 2 2 6 1 5 3...

Page 5: ...FinishControl 5500 3 2 1 2 1 4 5 6 1 2 4 7 8 9 10 5 t 1 3 6 3...

Page 6: ...IN WORK_____________________________ 8 11 TRANSPORTATION____________________________ 8 12 TAKING OUT OF OPERATION AND CLEANING ____ 8 12 1 Assembly______________________________________8 13 MAINTENANC...

Page 7: ...FF position before inserting the plug into the socket Accidents can occur if you carry the power tool whileyourfingerisontheswitchorifyouconnectthepower tool to the power supply which it is on d Remov...

Page 8: ...ctive clothing gloves and if necessary protective skin cream is required to protect the skin 4 Warning When working with the paint spraying system both indoors and outdoors care should be taken that n...

Page 9: ...Paint System the front part of the gun spray attachment can be replaced quickly and easily This enables a rapid material change without cleaning and ensures that the right tool is available for every...

Page 10: ...terial volume can be conveniently made directly on the gun 6 COATING MATERIAL 6 1 COATING MATERIALS SUITABLE FOR USE Solvent based and water soluble lacquer paints Mordants glazes impregnations oils c...

Page 11: ...e rearwards Fig 7 B 8 STARTING OPERATION Before connecting to the mains supply make sure that the mains voltage corresponds to the operating voltage on the rating plate The unit must be connected with...

Page 12: ...se in solvent only wipe 7 Move the air cap Fig 13 1 to the vertical position for easier removal and lift it off 8 Unscrew the union nut fig 13 2 9 Clean the air cap fig 14 1 and nozzle 3 with a brush...

Page 13: ...quired Warning Do not connect the blue or brown wire to the earth terminal of the plug The wires in this mains lead are coloured in accordance with the following code blue neutral brown live As the co...

Page 14: ...ume too large Nozzle contaminated Viscosity of coating material too high Too little pressure build up in container Air filter heavily soiled Amount of air too low Air hose damaged Air cap assembled in...

Page 15: ...tins maximum dimensions 112 mm h 132 mm 15 2 SPARE PARTS FINISHCONTROL 5500 FIG 21 POS ORDER NO DESIGNATION 1 2434503 Filter cover set 2 2434505 Air filter 4 pcs 3 2434506 Storage compartment cover 4...

Page 16: ...ion of conformity is enclosed with the product If required it can be re ordered using order number 2434454 3 2 YEAR GUARANTEE ON THIS WAGNER CONTRACTOR PRODUCT Status 03 03 2022 WAGNER exclusively pro...

Page 17: ...13 FinishControl 5500 EN...

Page 18: ...14 FinishControl 5500 EN...

Page 19: ...15 FinishControl 5500 EN...

Page 20: ...22 9450 Altst tten Schweiz Tel 41 71 7 57 22 11 Telefax 41 71 7 57 22 22 wagner wagner group ch F Euromair Antony S A V Ile de France 12 14 av F Sommer 92160 Antony Tel 01 55 59 92 42 Telefax 33 0 1...

Reviews: