background image

12

FinishControl 5500

 

EN

TESTING OF THE UNIT

For safety reasons, we would recommend having the device 

checked by an expert as required but at least every 12 months 

to ensure that it can continue to operate safely.

In the case of unused devices, the check can be postponed 

until they are next started up.

All (potentially deviating) national inspection and mainte-

nance regulations must also be observed.

If you have any questions, please contact the customer service 

team at Wagner.

IMPORTANT INFORMATION ON PRODUCT LIABILITY

An EU directive valid since 01.01.1990 specifies that the manu-

facturer is only liable for his products if all the parts originate 

from the manufactured or are approved by him, and if the 

units are mounted and operated properly.

If accessories or spare parts from third parties are used, li-

ability can be partially or completely inapplicable. In extreme 

cases the responsible authorities can prohibit the use of the 

entire unit (German industrial employer‘s liability insurance 

association and factory inspectorate). 

With original WAGNER accessories and spare parts, compli-

ance with all safety regulations is guaranteed.

NOTE ON DISPOSAL 

In observance of the European Directive 2012/19/EU on waste 

electrical and electronic equipment and implementation in 

accordance with national law, this product is not to be dis-

posed of together with household waste material but must be 

recycled in an environmentally friendly way!

Wagner or one of our dealers will take back your used Wagner 

waste electrical or electronic equipment and will dispose of 

it for you in an environmentally friendly way. Please ask your 

local Wagner service centre or dealer for details or contact us 

direct.

EU Declaration of conformity

We declare under sole responsibility that this product 

conforms to the following relevant stipulations:  

2006/42/EC, 2014/30/EU, 2011/65/EU, 2012/19/EU 

Applied harmonised norms:  

EN 62841-1, EN 50580, EN IEC 55014-1, EN IEC 55014-2,  

EN IEC 61000-3-2, EN 61000-3-3, EN 62233

  

 

The EU declaration of conformity is enclosed with the 

product.  

If required, it can be re-ordered using order number 

2434454.

3 + 2 YEAR GUARANTEE ON THIS WAGNER CONTRACTOR 

PRODUCT

(Status 03.03.2022)

WAGNER exclusively provides the commercial buyer who has 

purchased the product from an authorised specialist dealer 

(hereinafter referred to as the „Customer“) with a guarantee  

for the products listed on the Internet at https://go.wagner-

group.com/3plus2-info in addition to the statutory warranty 

regulations, unless there is a guarantee  exclusion.

The guarantee period for WAGNER products (devices) in the 

contractor‘s sector is 36 months and begins with the date 

of purchase of the initial purchase. This guarantee period 

is extended by a further 24 months if the product is regis-

tered within 28 days of purchase on the Internet at https://

go.wagner-group.com/3plus2.

In cases of commercial rental, industrial use (e.g. use in shift 

operation) or equivalent use, the guarantee period is 12 

months due to the significantly higher load. We reserve the 

right to carry out a check in individual cases and refuse the 

guarantee where necessary.

If any material, machining or performance defects are identi-

fied in the device within the guarantee period, then the gua-

rantee claims must be made immediately and within a period 

of no more than 2 weeks following discovery of the defect.

The detailed guarantee conditions can be obtained on  

request from our authorised WAGNER partners (see website 

or operating instructions) or in text form on our website:

https://go.wagner-group.com/pf-warranty-conditions

Subject to modifications

UKCA Declaration of conformity

We declare under sole responsibility that this product 

conforms to the following relevant regulations:  

 

Supply of Machinery (Safety) Regulations 2018 

Electromagnetic Compatibility Regulations 2016 

The Restriction of the Use of Certain Hazardous Substances in 

Electrical and Electronic Equipment Regulations 2012 

The Waste Electrical and Electronic Equipment Regulations 

2013 

 

Applied harmonised standards  

BS EN 62841-1, BS EN 50580, BS EN IEC 55014-1,  

BS EN IEC 55014-2, BS EN 61000-3-2, BS EN 61000-3-3,  

BS EN 62233

TESTING OF THE UNIT / INFORMATION ON PRODUCT LIABILITY / GUARANTEE DECLARATION

Summary of Contents for FinishControl 5500

Page 1: ...FINISH CONTROL 5500 OPERATING MANUAL wagner group com EN...

Page 2: ...FinishControl 5500 1 1 2 3 A A B 1 c 24 3 2 11 12 1 13 9 5 4 14 23 18 25 7 6 8 15 16 17 19 20 21 22 10...

Page 3: ...FinishControl 5500 A B 2 1 1 1 1 3 10 cm 1 2 1 2...

Page 4: ...FinishControl 5500 r 1 q 1 s 1 3 2 2 6 1 5 3...

Page 5: ...FinishControl 5500 3 2 1 2 1 4 5 6 1 2 4 7 8 9 10 5 t 1 3 6 3...

Page 6: ...IN WORK_____________________________ 8 11 TRANSPORTATION____________________________ 8 12 TAKING OUT OF OPERATION AND CLEANING ____ 8 12 1 Assembly______________________________________8 13 MAINTENANC...

Page 7: ...FF position before inserting the plug into the socket Accidents can occur if you carry the power tool whileyourfingerisontheswitchorifyouconnectthepower tool to the power supply which it is on d Remov...

Page 8: ...ctive clothing gloves and if necessary protective skin cream is required to protect the skin 4 Warning When working with the paint spraying system both indoors and outdoors care should be taken that n...

Page 9: ...Paint System the front part of the gun spray attachment can be replaced quickly and easily This enables a rapid material change without cleaning and ensures that the right tool is available for every...

Page 10: ...terial volume can be conveniently made directly on the gun 6 COATING MATERIAL 6 1 COATING MATERIALS SUITABLE FOR USE Solvent based and water soluble lacquer paints Mordants glazes impregnations oils c...

Page 11: ...e rearwards Fig 7 B 8 STARTING OPERATION Before connecting to the mains supply make sure that the mains voltage corresponds to the operating voltage on the rating plate The unit must be connected with...

Page 12: ...se in solvent only wipe 7 Move the air cap Fig 13 1 to the vertical position for easier removal and lift it off 8 Unscrew the union nut fig 13 2 9 Clean the air cap fig 14 1 and nozzle 3 with a brush...

Page 13: ...quired Warning Do not connect the blue or brown wire to the earth terminal of the plug The wires in this mains lead are coloured in accordance with the following code blue neutral brown live As the co...

Page 14: ...ume too large Nozzle contaminated Viscosity of coating material too high Too little pressure build up in container Air filter heavily soiled Amount of air too low Air hose damaged Air cap assembled in...

Page 15: ...tins maximum dimensions 112 mm h 132 mm 15 2 SPARE PARTS FINISHCONTROL 5500 FIG 21 POS ORDER NO DESIGNATION 1 2434503 Filter cover set 2 2434505 Air filter 4 pcs 3 2434506 Storage compartment cover 4...

Page 16: ...ion of conformity is enclosed with the product If required it can be re ordered using order number 2434454 3 2 YEAR GUARANTEE ON THIS WAGNER CONTRACTOR PRODUCT Status 03 03 2022 WAGNER exclusively pro...

Page 17: ...13 FinishControl 5500 EN...

Page 18: ...14 FinishControl 5500 EN...

Page 19: ...15 FinishControl 5500 EN...

Page 20: ...22 9450 Altst tten Schweiz Tel 41 71 7 57 22 11 Telefax 41 71 7 57 22 22 wagner wagner group ch F Euromair Antony S A V Ile de France 12 14 av F Sommer 92160 Antony Tel 01 55 59 92 42 Telefax 33 0 1...

Reviews: