16
EN
CLEANUP
FLUSHING THE UNIT
Special cleanup instructions for use with
flammable solvents (must have a flashpoint
above 100˚F (38˚C):
•
Always flush spray gun outside.
•
Area must be free of flammable vapors.
•
Cleaning area must be well-ventilated.
•
Do not submerge turbine!
1.
Remove the battery. Loosen the material container by 1/2
turn, but do not remove it. This will relieve any pressure
left over in the system.
Pull the trigger so that the material inside the spray nozzle
drains back into the container.
2.
Unscrew the container and remove. Empty any remaining
material back into the material container.
3.
Pour a small amount of the appropriate cleaning solution
into the cup (Water=1/2 full. Mineral spirits=1/4 full).
4.
Attach the cup to the nozzle and replace the battery.
5.
Spray the cleaning solution into a safe area.
While spraying, gently shake the spray gun. This slight
agitation will help break up smaller particles of spray
material.
6.
Remove the battery. Loosen the material container by 1/2
turn, but do not remove it. This will relieve any pressure
left over in the system.
Pull the trigger so that the material inside the spray nozzle
drains back into the container.
Attention
If you cleaned the sprayer using mineral
spirits, repeat steps 1-6 using warm, soapy
water.
i
When cleaning, use the appropriate
cleaning solution (warm, soapy water for
latex materials; mineral spirits for oil-based
materials).
Move on to “Cleanup - Cleaning
the Nozzle”, next page.
1
1/2
PULL
2
3
4
5
EMPTY WASTE
CONTAINER
6
1/2
PULL