27
GA 4000ACIC
milli Pascal x
Sec mPas
Centipoise
Poise
DIN Cup
4 mm ; 0.16 inch
Ford Cup 4
Zahn 2
10 10 0.1
5 16
15 15 0.15
8 17
20 20 0.2
10 18
25 25 0.25 14 12 19
30 30 0.3 15 14 20
40 40 0.4 17 18 22
50 50 0.5 19 22 24
60 60 0.6 21 26 27
70 70 0.7 23 28 30
80 80 0.8 25 31 34
90 90 0.9 28 32 37
100
100 1 30 34 41
120 120 1.2 33 41 49
140 140 1.4 37 45 58
160 160 1.6 43 50 66
180 180 1.8 46 54 74
200
200 2 49 58 82
220 220 2.2 52 62
240 240 2.4 56 65
260 260 2.6 62 68
280 280 2.8 65 70
300 300 3 70 74
320 320 3.2
340 340 3.4
360 360 3.6 80
380 380 3.8
400 400 4 90
OPERATING MANUAL
EDITION 06/ 2011
PART NO. DOC2312956
5.2.1
VISCOSITY CONVERSION TABLE
The viscosity of the paints is of great importance. The best results are obtained for paints
of 80 and 150 mPas.
Processing of up to 260 mPas is generally possible without problem, if high coating
thicknesses are required. It is important for the optimal coating quality that the lacquer
temperature is kept constant during the coating.
In the case of application problems contact the paint producer.
5.2
PREPARATION OF PAINTS