6.1
SHUTTING DOWN AND CLEANING
1. Relieve the pressure of gun and unit.
2. Secure gun (Remove the control air hose).
3. Connect up the supply of cleaning solvent.
4. Remove AirCoat nozzle and clean separately (see chapter 5.4.3).
5. Pressurize the cleaning supply to approx. 4 MPa; 40 bar; 580 psi and thoroughly fl ush
the spray gun.
6. Relieve the pressure of gun and unit.
7. Secure gun (Remove the control air hose).
8. Clean external the spray gun with a cleaning agent recommended by the manufacturer
and dry with a cloth or blow gun.
SIHI_0064_GB
CAUTION
Solvent in air conduit!
Problems
By cleaning the spraygun use with min. 0.05 MPa; 0.5 bar; 7.25 psi shaping air.
Cleaning solvent must not get into the air ducts.
DANGER
Exploding gas/ air mixture!
Danger to life from flying parts and burns
Never spray into a closed container.
Earth the container.
SIHI_0008_GB
WARNING
Explosive atmosphere!
Explosive gases are produced when aluminium comes into contact
with halogenized hydrocarbons
To clean aluminium, do not use liquids containing halogenized
hydrocarbons.
SIHI_0009_GB