21
VERSION 05/2018
ORDER NUMBER DOC 2312956
GA 4000ACIC
5.2.2 MODE "NC" AND "C"
DANGER
Spurting out of liquids with high pressure!
Danger to life and equipment damage.
For the operating mode NC (no product circulation), the spray gun may only be
connected if the lock pin is installed.
5.2.2.1 MODE "NC" WITHOUT PRODUCT CIRCULATION
In this mode of operation, the left or the right
product channel in the gun head (A) is locked by
the lock pin (M) and the product entrance (ME) is
always on the opposite side.
B_03069
ME
B
D
A
4x 4 Nm; 2.95 lbft
M
5.2.2.2 MODE "C" WITH PRODUCT CIRCULATION
In this mode of operation, the lock pin (M)
must be removed from the left or right product
channel in the gun head (A). Screw on additional
connection fitting (J). The product entrance (ME)
and the product return (MR) are freely selectable
in this mode of operation.
B_03489
B
D
M
J
A
ME
MR
4x 4 Nm; 2.95 lbft
Summary of Contents for GA 4000ACIC-S
Page 1: ...Version 05 2018 GA 4000ACIC S GA 4000ACIC R AirCoat Automatic spray gun II 2G X B_06647...
Page 2: ......
Page 66: ......
Page 67: ......