5.2.3 SPRAYING PROCEDURE
5.2.3.1 AIRCOAT FLAT SPRAYING PROCEDURE
For normal applications with the AirCoat flat jet process, the spray product is atomized at
a pressure of 3-12 MPa; 30-120 bar; 435-1740 psi. For normal applications, a soft, optimum
spray jet is achieved with help of the atomizing air, which has a pressure of 0.05-0.25 MPa;
0.5-2.5 bar; 7.2-36 psi. This eliminates most overlapping problems in the peripheral zones.
The shaping air allows the width of the spray jet to be increased or decreased.
B_03073
Variable spray jet width
Air cap
Shaping air
Atomizing air
Advantages:
– Large application volume.
– Low fogging tendency.
– Good finish.
– High-viscosity products can easily be applied.
– Jet width adjustment.