4.1.2 A SAFE WORK ENVIRONMENT
Hazard due to dangerous fluids or vapors!
Severe or fatal injuries due to explosion hazard or inhalation, swallowing or contact with
the skin or eyes.
Ensure that the floor in the working are is static dissipative in accordance with
EN 61340-4-1 (resistance must not exceed 100 M ).
Paint mist extraction systems/ventilation systems must be fitted on site according
to local regulations.
Make sure that the ground connection and potential equalization of all system parts
are reliable and continuous and can withstand the expected stress (e.g. mechanical
stress, corrosion).
Ensure that product/air hoses that have been adapted to the working pressure are
used.
Ensure that personal protective equipment (see Chapter
) is available and is
used.
Ensure that all persons within the working area wear static dissipative shoes.
Footwear must comply with EN 20344. The measured insulation resistance must not
exceed 100 M .
Protective clothing, including gloves, must comply with EN 1149-5. The measured
insulation resistance must not exceed 100 M .
Ensure that there are no ignition sources such as naked flames, sparks, glowing
wires, or hot surfaces in the vicinity. No smoking.
Ensure that the pipe joints, hoses, equipment parts and connections are
permanently, technically leak-proof:
– Periodic preventative maintenance and service (replacing hoses, checking
tightness of connections, etc.).
– Regular monitoring of leaks and defects via visual inspection and odor testing,
e.g. daily before commissioning, at the end of work or weekly.
In the event of defects, immediately bring the device or system to a stop and
arrange to have repairs carried out immediately.
4.1.3 PERSONNEL QUALIFICATIONS
Hazard due to incorrect use of device!
Risk of death due to untrained personnel.
Ensure that the operating personnel has been instructed by the operator in
accordance with the operating manual and the operating instructions. The device
must only be operated, maintained and repaired by trained personnel. Refer to the
operating instructions for information about the required personnel qualifications.