37
GA 5000EAC
1.0 AT
I
0
Main Switch
Hauptschalter
Prim. Fuse
Sicherung
Mains power IN
Netz Eingang
Air input
6 - 8bar
87-116 psi
Clean and dry air
Saubere und trockene Luft
6.5.2 (ISO 8573-1:2010)
Air input
Lufteingang
Control air
Steuerluft
Fan air
Formluft
Atomizing air
Zerstäuberluft
Spraygun
Sprühpistole
Interface
Schnittstelle
IN CAN Bus OUT
Data and Interlock
Daten und Verriegelung
CAN
Address
Service
Port
Restrictor for air during cleaning
Drossel für Luft während dem Spülen
Imax. = 1.0A
Umax. = 20Vpp
0102
II (2) G
SIRA 16 ATEX 5290X
Typ / Type:
EPG 5000
115VAC - 230VAC
50Hz / 60Hz
2359451
max. 40W
Wagner International AG
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Serie Nr.:
Serial No.:
Spannung:
Voltage:
Artikel Nr.:
Article No.:
Eingangsleistung:
Input Power:
Schutzart:
IP Code:
Norm:
Standard:
EN 50176:2009
IP 40
Eingangsstrom:
Input Current:
max. 0.5A
EN 50050-1:2013
Baujahr:
Year of manufacture:
0
1
2
34
5 67
8
9
0
1
2
34
5 67
8
9
B_05727
8
9
GA 5000
EPG 5000
7
1
2
3
4
5
6
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
6.4.3
CONNECTING GA 5000EACEC
1 for the product supply system
4 Control air hose
7 Control cable
2 Shaping air hose
5 Gun cable
8 Grounding cable
3 Atomizing air hose
6 for the compressed air supply
9 Mains cable
Incorrect installation/operation!
Risk of injury and damage to the device.
When commissioning and for all work, read and follow the
operating manual and safety regulations for the additionally
required system components.
WARNING
Procedure:
1.
Place the control unit outside the explosion zone.
2.
Mount spray gun to an grounded gun mounting.
3.
Connect the grounding cable to the control unit and the signal ground.
4.
Connect the gun connection cable to the control unit.
5.
Connect the control unit to the higher-level controller (if available).
6.
Connect the air hoses to the control unit and the spray gun in accordance with the
fi gure below.
7.
Set all airs to "0" using the regulator on the front side of the control unit.
8.
Connect the control unit to the compressed air supply.
9.
Connect the spray gun to the product supply system.
10. Connect the control unit to the power supply.
Summary of Contents for GA 5000EACIC
Page 2: ......
Page 106: ...106 GA 5000EAC OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360922 ...
Page 107: ......