42
GA 5000EAC
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
6.5
PREPARATION OF LACQUER
6.5.1
VISCOSITY CONVERSION TABLE
mPa s
10
10
0.1
5
16
15
15
0.15
8
17
20
20
0.2
10
18
25
25
0.25
14
12
19
30
30
0.3
15
14
20
40
40
0.4
17
18
22
50
50
0.5
19
22
24
60
60
0.6
21
26
27
70
70
0.7
23
28
30
80
80
0.8
25
31
34
90
90
0.9
28
32
37
100
100
1
30
34
41
120
120
1.2
33
41
49
140
140
1.4
37
45
58
160
160
1.6
43
50
66
180
180
1.8
46
54
74
200
200
2
49
58
82
220
220
2.2
52
62
240
240
2.4
56
65
260
260
2.6
62
68
280
280
2.8
65
70
300
300
3
70
74
320
320
3.2
340
340
3.4
360
360
3.6
80
380
380
3.8
400
400
4
90
The viscosity of the lacquer is of great importance. The best spraying results are obtained
with values between 25 and 40 DIN/4 seconds (measured in immersion fl ow cup DIN 4 mm;
0.16 inches).
Processing of up to 60 DIN/4 seconds is generally possible without problem if high coating
thicknesses are required.
With the WAGNER AirCoat fl at jet spraying process, the diff erent viscosities of the lacquer
are optimally covered by two air cap types. These can be found in "Accessories".
In the case of application problems contact the lacquer manufacturer.