54
GA 5000EAC
B_05755
Y
1
9
10
11
12
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
7.3.8
REPLACING THE AIRCOAT FLAT JET NOZZLES
1.
Switch off control unit.
2.
Unscrew union nut completely (12) and remove air cap (10).
3.
Remove and clean the ACF 5000 AirCoat nozzle (11).
Defective AirCoat nozzle!
Insuffi
cient paint application quality.
Do not use sharp-edged objects to treat carbide on the AirCoat nozzle.
NOTICE
4.
Insert new ACF5000 nozzle (11) into the valve housing.
5.
Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces.
6.
Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
7.
Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.