Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Never spray into a closed tank.
Ground the tank.
DANGER
Clean nozzle
1. Switch off control unit.
2. Dismount nozzle and clean separately Chapter 7.3.
Flush spraying system and spray gun
3. Connect spraying system to fl ushing agent supply in accordance with operating
manual for the product pressure generator.
4. Point the spray gun toward the collection tray and switch it on. Switch off gun as
soon as clean fl ushing agent emerges.
5. Remove fl ushing agent supply.
Blowing out the air passages of the spray gun
6. Close pump pressure regulator. Switch on compressed air supply on the control unit,
open air pressure regulator for shaping and atomizing air.
7. Actuate the spray gun without activated high voltage and thoroughly blow out the
air passages.
8. For switching off the shaping and atomizing air press the "Standby" button on the
control unit.
9. Switch off the compressed air supply.
Clean the outside of the spray gun
10. Clean the spray gun body and other components of the spraying system with a
cleaning agent recommended by the lacquer manufacturer and dry with a cloth or
blow gun.
Cleaning the nozzle parts
see Chapter 7.3.9
Eliminating nozzle clogging
see Chapter 7.3.10