2.6
REASONABLY FORESEEABLE MISUSE
2.7
RESIDUAL RISKS
Residual risks are risks which cannot be ruled out even in the event of correct use.
If necessary, warning and prohibition signs at the relevant points of risk indicate residual
risks.
Residual risk
Source
Consequences
Specifi c measures
Lifecycle phase
Skin contact with
lacquers and
cleaning agents
Handling of
lacquers and
cleaning agents
Skin irritations,
Wear protective
clothing
Operation,
allergies
maintenance,
Observe safety data
sheets
disassembly
Lacquer in air
outside the defi ned
working area
Lacquering outside
the defi ned working
area
Inhalation of
substances
hazardous to health
Observe work and
operation instructions
Operation,
maintenance
The forms of misuse listed below may result in physical injury or property damage:
use with non-authorized control units;
coating work pieces which are not grounded;
working with an ungrounded lacquer supply system;
performing unauthorized conversions or modifi cations to the device;
processing inadmissible coating products;
processing dry or similar coating products, e.g., powder;
using defective components, spare parts or accessories other than those described in
the "Accessories" chapter of this operating manual;
continuing work with a defective or kinked product hose;
working with incorrectly set values;
processing food.