46
GA 5000EA
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360924
6.6
PREPARATION OF LACQUER
6.6.1
VISCOSITY CONVERSION TABLE
mPa s
10
10
0.1
5
16
15
15
0.15
8
17
20
20
0.2
10
18
25
25
0.25
14
12
19
30
30
0.3
15
14
20
40
40
0.4
17
18
22
50
50
0.5
19
22
24
60
60
0.6
21
26
27
70
70
0.7
23
28
30
80
80
0.8
25
31
34
90
90
0.9
28
32
37
100
100
1
30
34
41
120
120
1.2
33
41
49
140
140
1.4
37
45
58
160
160
1.6
43
50
66
180
180
1.8
46
54
74
200
200
2
49
58
82
220
220
2.2
52
62
240
240
2.4
56
65
260
260
2.6
62
68
280
280
2.8
65
70
300
300
3
70
74
320
320
3.2
340
340
3.4
360
360
3.6
80
380
380
3.8
400
400
4
90
The viscosity of the lacquer is of great importance. The best spraying results are obtained
with values between 15 and 30 DIN/4 seconds (measured in immersion fl ow cup DIN 4 mm;
0.16 inches).
In the case of application problems contact the lacquer manufacturer.