54
GA 5000EA
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360924
7.3.3
PRESSURE RELIEF/WORK INTERRUPTION
Process for relieving pressure
1.
Switch off high voltage at the control unit.
2.
Turn compressed air regulator for shaping and atomizing air on the EPG 5000 to "0".
3.
Close the compressed air supply on the material side upon the product pressure
generator.
4.
Relieve the pressure of gun and system, e.g., by switching on gun without high voltage.
5.
Fill fl ushing agent and adjust pressure.
6.
Thoroughly fl ush out the spray gun.
7.
Relieve the pressure on the gun and the system.
8.
Clean gun and dry it with a cloth or a blow gun.
The pressure must always be relieved when:
- The spraying tasks are fi nished.
- The spraying system is maintained.
- Cleaning tasks are carried out on the spraying system.
- The spraying system is moved to another location.
- Something must be checked on the spraying system.
- The valve seat is replaced on the gun.
Observe general safety instructions in Chapter 4.
High-pressure spray jet!
Danger to life from injecting paint or solvent.
Never reach into the spray jet.
Never point the spray gun at people.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high-pressure parts; instead relieve the pressure
from them and replace them.
Wear the appropriate protective clothing, gloves, eyewear and
respiratory protection.
WARNING
Summary of Contents for GA 5000EAEC
Page 2: ......
Page 106: ...106 GA 5000EA OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360924...
Page 107: ......