84
GA 5000EA
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360924
Connect the product hose to the spray gun.
Test the seal of the spray gun with suitable medium (e.g., fl ushing agent or Marcol 52) and
a maximum pressure of 0.8 MPa; 8 bar; 116 psi. Increase the pressure gradually while doing
so.
Observe the following gun components:
Product connection, nozzle body, product valve (no post-spraying).
11.2
AIR TEST
11.3
PRODUCT PRESSURE TEST
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
Never spray into a closed tank.
Ground the tank.
DANGER
11.4
TEST OF SPRAY PATTERN
Check spray pattern in accordance with Chapter 7.3.1
GA 5000EA
Switch off the atomizing and shaping air, switch on control air.
1. 0.4 MPa; 4 bar; 58 psi: The air valve must switch on correctly.
2. 0.8 MPa; 8 bar; 116 psi: Test for air seal.
3. Switch off control air: The air valve must switch off correctly.
Summary of Contents for GA 5000EAIC
Page 2: ......
Page 106: ...106 GA 5000EA OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360924...
Page 107: ......